Electrical – DC / Low Frequency
Parameter |
Range |
Best System Accuracy |
Comments |
|
|
|
|
DC Voltage System |
|
|
|
|
|
|
|
Generate |
|
|
|
|
10 mV – 105 mV |
± (0.2% iv + 0.05% fs) |
Arbiter 1040C |
|
0.1 V – 1.05 V |
± (0.2% iv + 0.05% fs) |
|
|
1 V – 10.5 V |
± (0.2% iv + 0.05% fs) |
|
|
10V – 105 V |
± (0.2% iv + 0.05% fs) |
|
|
100 V – 1050 V |
± (0.2% iv + 0.05% fs) |
|
DC Current System |
|
|
|
|
|
|
|
Generate |
|
|
|
|
0.10 mA – 1.05 mA |
± (0.2% iv + 0.05% fs) |
Arbiter 1040C |
|
1.00 mA – 10.5 mA |
± (0.2% iv + 0.05% fs) |
|
|
10.0 mA – 105 mA |
± (0.2% iv + 0.05% fs) |
|
|
0.100 A – 1.05 A |
± (0.2% iv + 0.05% fs) |
|
|
1 A – 10.5 A |
± (0.2% iv + 0.05% fs) |
|
|
|
|
|
Electrical – AC / Low Frequency
Parameter/Range |
Frequency (Hz) |
Best System Accuracy |
Comments |
|
|
|
|
AC Voltage System |
|
|
|
|
|
|
|
Generate |
|
|
|
1.5 V – 15.75 V |
50 – 75 |
± (0.2% iv + 0.05% fs) |
Arbiter 1040C |
|
333.3 – 500 |
± (0.2% iv + 0.05% fs) |
|
15V – 157.5 V |
50 – 75 |
± (0.2% iv + 0.1% fs) |
|
|
333.3 – 500 |
± (0.2% iv + 0.1% fs) |
|
150 V – 750.0 V |
50 – 75 |
± (0.2% iv + 0.1% fs) |
|
|
333.3 – 500 |
± (0.2% iv + 0.1% fs) |
|
|
|
|
|
AC Current System |
|
|
|
|
|
|
|
Generate |
|
|
|
.1 A – 1.05 A |
50 – 75 |
± (0.2% iv + 0.05% fs) |
Arbiter 1040C |
|
333.3 – 500 |
± (0.2% iv + 0.05% fs) |
|
1 A – 7.5 A |
50 – 75 |
± (0.2% iv + 0.1% fs) |
|
|
333.3 – 500 |
± (0.2% iv + 0.1% fs) |
|
Phase |
|
|
|
|
|
|
|
Generate |
|
|
|
-180° to +180° |
60 Hz and 400 Hz |
± 0.33° |
Arbiter 1040C |
|
|
|
|
AC Power / VARS |
|
|
|
|
|
|
|
Generate |
|
|
|
1.5 VA – 165 VA |
400 |
≤ (0.06% iv + 0.03% fs) |
Arbiter 1040C |
15 VA – 825 VA |
400 |
≤ (0.06% iv + 0.03% fs) |
|
15 VA – 785 VA |
60 |
≤ (0.06% iv + 0.03% fs) |
|
150 VA – 5625 VA |
60 |
≤ (0.06% iv + 0.03% fs) |
|
|
|
|
|
Physical / Mechanical
Parameter |
Range |
Best System Accuracy |
Comments |
|
|
|
|
Pressure |
-14.5psig to 6,000psig |
-14.5psig to 0psig / |
XP2i Crystal Pressure |
|
|
± 0.25% of fs* |
Gages |
|
|
0 to 20% of Range / |
*full scale = -14.5psig |
|
|
± 0.02% of fs |
*only 30 & 300psig gages |
|
|
20 to 110% of Range / |
|
|
|
± 0.1% of iv |
|
|
|
|
|
Torque |
0 to 800 Lb Ft |
± 0.1% iv |
AKO TSD650PBAT2N2 |
|
|
|
|
|
|
|
|
Temperature
Parameter |
Range |
Best System Accuracy |
Comments |
|
|
|
|
Generate |
100 to 600 °F |
± 1% up to 600°F |
King Nutronics 3604 |
|
600 to 1200 °F |
± 0.2% iv |
|
|
|
|
|
|
-40 to 250 °F |
± 0.5 °F |
King Nutronics 3605 |
|
|
|
|
|
|
|
|
Contact
Phone: |
|
General Enquiry |
East Coast Contact |
|
|
Email: |
|
|
|
Office |
2727 Hoover Ave. Ste. 200 National City, CA 91950
|
Open Positions: Currently, there are no positions available. Please check again.
|
|
To submit your resume for positions when they become available, Please submit your resume: |
|
|
|
Fax |
(858) 777-8640 |
|
|
Regular Mail |
Attention: Human Resource, 301 Mission Rd. Ste. 505 Oceanside, CA 92054 |
|
|
Thank you for submitting your resume. |